Sign In | Join Free | My burrillandco.com
Home > RUO Test Kit >

Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use

Biovantion Inc.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use from wholesalers
     
    Buy cheap Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use from wholesalers
    • Buy cheap Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use from wholesalers
    • Buy cheap Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use from wholesalers

    Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use

    Ask Lasest Price
    Model Number : In-Hu4090
    Price : Negotiable
    Payment Terms : L/C, Western Union, T/T
    Supply Ability : 1000kits/week
    Delivery Time : 5-8 working days
    Brand Name : BIOVANTION
    • Product Details
    • Company Profile

    Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use

    Human Vitamin D3;VD3 ELISA Kit

    • Expiration date:six months .
    • Storage: 2-8℃.
    • Our Human Vitamin D3 (VD3) ELISA kit is to assay Vitamin D3 (VD3) levels in Human serum, plasma, culture media or any biological fluid.

    Principle

    This ELISA kit uses Sandwich-ELISA as the method. The Microelisa stripplate provided in this kit has been pre-coated with an antibody specific to Vitamin D3 (VD3) . Standards or samples are added to the appropriate Microelisa stripplate wells and combined to the specific antibody. Then a Horseradish Peroxidase (HRP)- conjugated antibody specific for Vitamin D3 (VD3) is added to each Microelisa stripplate well and incubated. Free components are washed away. The TMB substrate solution is added to each well. Only those wells that contain Vitamin D3 (VD3) and HRP conjugated Vitamin D3 (VD3) antibody will appear blue in color and then turn yellow after the addition of the stop solution. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of Vitamin D3 (VD3) . You can calculate the concentration of Vitamin D3 (VD3) in the samples by comparing the OD of the samples to the standard curve.

    Materials provided with the kit

    Materials provided with the kit48 determinations96 determinationsStorage
    1User manual11R.T.
    2Closure plate membrane22R.T.
    3Sealed bags11R.T.
    4Microelisa stripplate112-8℃
    5Standard:45ng/ml0.5ml×1 bottle0.5ml×1 bottle2-8℃
    6Standard diluent1.5ml×1 bottle1.5ml×1 bottle2-8℃
    7HRP-Conjugate reagent3ml×1 bottle6ml×1 bottle2-8℃
    8Sample diluent3ml×1 bottle6ml×1 bottle2-8℃
    9Chromogen Solution A3ml×1 bottle6ml×1 bottle2-8℃
    10Chromogen Solution B3ml×1 bottle6ml×1 bottle2-8℃
    11Stop Solution3ml×1 bottle6ml×1 bottle2-8℃
    12Wash solution20ml (20X)×1bottle20ml (30X)×1bottle2-8℃
    • Dilution of Standards

    Ten wells are set for standards in a Microelisa stripplate. In Well 1 and Well 2, 100μl Standard solution and 50μl Standard Dilution buffer are added and mixed well. In Well 3 and Well 4, 100μl solution from Well 1 and Well 2 are added respectively. Then 50μl Standard Dilution buffer are added and mixed well. 50μl solution is discarded from Well 3 and Well 4. In Well 5 and Well 6, 50μl solution from Well 3 and Well 4 are added respectively. Then 50μl Standard Dilution buffer are added and mixed well. In Well 7 and Well 8, 50μl solution from Well 5 and Well 6 are added respectively. Then 50μl Standard Dilution buffer are added and mixed well. In Well 9 and Well 10, 50μl solution from Well 7 and Well 8 are added respectively. Then 50μl Standard Dilution buffer are added and mixed well. 50μl solution is discarded from Well 9 and Well 10. After dilution, the total volume in all the wells are 50μl and the concentrations are 30 ng/ml, 20 ng/ml, 10 ng/ml, 5 ng/ml and 2.5 ng/ml, respectively.


    Calculation of Results

    Known concentrations of Human Vitamin D3 (VD3) Standard and its corresponding reading OD is plotted on the log scale (x-axis) and the log scale (y-axis) respectively. The concentration of Human Vitamin D3 (VD3) in sample is determined by plotting the sample’s O.D. on the Y-axis. The original concentration is calculated by multiplying the dilution factor.

    Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Human Vitamin D3 (VD3) were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Human Vitamin D3 (VD3)were tested on 3 different plates, 8 replicates in each plate.

    CV(%) = SD/meanX100

    Intra-Assay: CV<10%

    Inter-Assay: CV<12%


    Assay range

    0.8 ng/ml -36 ng/ml


    Sensitivity:

    0.3 ng/ml

    • Store the kit at 4°C upon receipt.The kit should be equilibrated to room temperature before the assay. Remove any unneeded strips from Human Vitamin D3 (VD3) Antibody-Coated plate, reseal them in zip-lock foil and keep at 4°C.
    • Standard curve should be included in every assay. Replicate wells are recommended. If the OD value of the sample is greater than the first well of standards, please dilute the sample (n times) before test. When calculating the original Vitamin D3 (VD3) concentration, please multiply the total dilution factor (XnX5).

    Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research UseSandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research UseSandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use


    Quality Sandwich Elisa VD3 RUO Test Kit Vitamin D3 Elisa Kit For Research Use for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Biovantion Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)